KE300A-04 single-phase motor series special inverter, based on the world's leading speed sensorless high-performance vector core control algorithm, combined with the unique start-up and control requirements of single-phase motor, using a new magnetic flux vector control technology to achieve true The two-phase orthogonal 90-degree magnetic flux vector control can be used without removing the capacitor.
This series of products has the characteristics of large starting torque and high efficiency of the whole machine, and has added some special functions of single-phase motors (such as current suppression, voltage suppression, jitter suppression, etc.)
The user does not need to make too many complicated settings when using it, but only needs to make simple parameter modification according to the actual use site.
It can be widely used in fan, water pump, power tool and other single-phase asynchronous motor drive applications.
(1) It is specially tailored for single-phase asynchronous motor. It is easy to install and debug, and the motor is not used for any modification to achieve stepless speed regulation.
(2) DSP high-speed control core
The control core adopts the high-speed digital processor DSP produced by TI (Texas Instruments).
(3) High starting torque and fast dynamic response
(4) Low motor noise and low temperature rise
(5) Strong instantaneous overcurrent capability
(6) Non-stop function when instantaneous power failure
(7) Robust EMC design
(8) Modular design, very flexible configuration
(9) Excellent robust performance can ensure that the load can start and stop quickly;
(10) Fast current limit function can quickly limit the current within the protection point, reducing the probability of frequent overcurrent alarm failure.
(11) High power factor output
(12) The built-in PID regulator can easily form a closed-loop control system for process quantities such as temperature, pressure, and flow.
(13) Adopt advanced power module drive mode, which can effectively suppress harmonics and eliminate interference to peripheral control loops and sensors during inverter operation.
(14) Perfect protection functions include overvoltage / undervoltage protection, overheat protection, ground fault protection, short circuit protection, overcurrent protection, overload protection, etc.
Item | Technical Index | Specification |
Input | Input voltage | 1AC 220V±15% |
Input frequency | 47~63Hz | |
Output | Output voltage | 0~rated input voltage |
Output frequency | V/f control: 0~3000Hz | |
Operation command mode | Keypad controlTerminal controlSerial communication control | |
Frequency setting mode | Digital setting, analog setting, pulse frequency setting, serial communication setting, multi-step speed setting & simple PLC, PID setting, etc. These frequency settings can be combined & switched in various modes. | |
Overload capacity | 150% 60s, 180% 10s, 200% 3s | |
Starting torque | 1Hz/150% (V/f) | |
Speed adjustment range | 1:50(V/f) | |
Carrier frequency | 1.0-16.0kHz,automatically adjusted according to temperature and load characteristics | |
Frequency accuracy | Digital setting: 0.01HzAnalog setting: maximum frequency * 0.05% | |
Torque boost | Automatically torque boost; manually torque boost: 0.1%~30.0% | |
V/f curve | Three types: linear, multiple point and square type (1.2 power, 1.4 power, 1.6 power, 1.8 power, square) | |
Acceleration/decele ration mode | Straight line/S curve; four kinds of acceleration/deceleration time, range: 0.1s~3600.0s | |
DC braking | DC braking when starting and stoppingDC braking frequency: 0.0Hz~maximum frequency, braking time: 0.0s~100.0s | |
Jog operation | Jog operation frequency: 0.0Hz~maximum frequencyJog acceleration/deceleration time: 0.1s~3600.0s | |
Simple PLC & multi-step speed operation | It can realize a maximum of 16 segments speed running via the built-in PLC or control terminal. | |
Built-in PID | Built-in PID control to easily realize the close loop control of the process parameters (such as pressure, temperature, flow, etc.) | |
Automatic voltage regulation | Keep output voltage constant automatically when input voltage fluctuating | |
Control Function | Common DC bus | Common DC bus for several inverters, energy balanced automatically |
Torque control | Torque control without PG | |
Torque limit | “Rooter” characteristics, limit the torque automatically and prevent frequent over-current tripping during the running process | |
Wobble frequency control | Multiple triangular-wave frequency control, special for textile | |
Timing/length/counting control | Timing/length/counting control function | |
Over-voltage & over-current stall control | Limit current & voltage automatically during the running process, prevent frequent over-current & over-voltage tripping | |
Fault protection function | Up to 30 fault protections including over-current, over-voltage, under-voltage, overheating, default phase, overload, shortcut, etc., can record the detailed running status during failure & has fault automatic reset function | |
Input/output terminals | Input terminals | Programmable DI: 5 on-off inputs, 1 high-speed pulse input1 programmable AI: AI1: 0~10V or 0/4~20mA |
Output terminals | 1 programmable open collector output: 1 analog output (open collector output or high-speed pulse output)1 relay output1 analog output: 0/4~20mA or 0~10V | |
Communication terminals | Offer RS485 communication interface, support MODBUS-RTU communication protocol | |
Human machine interface | LED display | Display frequency setting, output frequency, output voltage, output current, etc. |
Multifunction key | QUICK/JOG key, can be used as multifunction key | |
Environment | Ambient temperature | -10℃~40℃, derated 4% when the temperature rise by every 1℃(40℃~50℃). |
Humidity | 90%RH or less (non-condensing) | |
Altitude | ≤1000M: output rated power, >1000M: output derated | |
Storage temperature | -20℃~60℃ | |
Storage environment | Indoor, no direct sunlight, dust, corrosive gas, flammable gas, oil mist, steam, dripping water, salt, vibration |
Inverter Model | Motor | Rated Input Current (A) | Rated Output Current (A) | |
KW | HP | |||
1AC 220V/230V/240V -15%~15% | ||||
KE300A-04-0R4G-S2 | 0.4 | 0.5 | 5.4 | 2.3 |
KE300A-04-0R7G-S2 | 0.75 | 1.0 | 8.2 | 4.0 |
KE300A-04-1R5G-S2 | 1.5 | 2.0 | 14.0 | 7.0 |
KE300A-04-2R2G-S2 | 2.2 | 3.0 | 23.0 | 9.6 |
KE300A-04-004G-S2 | 4.0 | 5.2 | 25.0 | 15.0 |
KE300A-04-5R5G-S2 | 5.5 | 7.2 | 38.0 | 23.0 |
KE300A-04-7R5G-S2 | 7.5 | 10.0 | 50.0 | 32.0 |