ME3000 is a high-performance engineering transmission product independently developed by Shenzhen MICNO Electric.
Combined with the needs of actual engineering applications, the ME3000 series has the characteristics of small size, strong function, and wide application range.
The ME3000 inverter integrates PG-free vector control, multi-stage V / f control, torque control, and soft start functions, and is widely used in fans, pumps and load control accuracy, torque response speed, and low-frequency torque output have high requirements Applications.
Wide Range of Applications
ME3000 inverter integrates PG-free vector control, multi-section V/f control, torque control and soft start function.It is widely used in wind turbines, pump loads and applications where speed control accuracy, torque response speed and low frequency torque output have high requirements.
Superior Performance
Optional LCD keyboard for more intuitive parameter debugging and real-time monitoring of operating status
Item | Technical Index | Specification |
Input | Input voltage | 1AC 220V±15%,3AC 220V±15%,3AC 380V±15%,3AC 660V±15% |
Input frequency | 47~63Hz | |
Output | Output voltage | 0~rated input voltage |
Output frequency | V/f control: 0~3000HzSensorless vector control: 0~300Hz | |
Operation command mode | Keypad controlTerminal controlSerial communication control | |
Frequency setting mode | Digital setting, analog setting, pulse frequency setting, serial communication setting, multi-step speed setting & simple PLC, PID setting, etc. These frequency settings can be combined & switched in various modes. | |
Overload capacity | G model: 150% 60s, 180% 10s, 200% 3s P model: 120% 60s, 150% 10s, 180% 3s | |
Starting torque | 0.5Hz/150% (SVC); 1Hz/150% (V/f) | |
Speed adjustment range | 1:100 (SVC), 1:50 (V/f) | |
Carrier frequency | 1.0-16.0kHz,automatically adjusted according to temperature and load characteristics | |
Frequency accuracy | Digital setting: 0.01HzAnalog setting: maximum frequency * 0.05% | |
Torque boost | Automatically torque boost; manually torque boost: 0.1%~30.0% | |
V/f curve | Three types: linear, multiple point and square type (1.2 power, 1.4 power, 1.6 power, 1.8 power, square) | |
Acceleration/decele ration mode | Straight line/S curve; four kinds of acceleration/deceleration time, range: 0.1s~3600.0s | |
DC braking | DC braking when starting and stoppingDC braking frequency: 0.0Hz~maximum frequency, braking time: 0.0s~100.0s | |
Jog operation | Jog operation frequency: 0.0Hz~maximum frequencyJog acceleration/deceleration time: 0.1s~3600.0s | |
Simple PLC & multi-step speed operation | It can realize a maximum of 16 segments speed running via the built-in PLC or control terminal. | |
Built-in PID | Built-in PID control to easily realize the close loop control of the process parameters (such as pressure, temperature, flow, etc.) | |
Automatic voltage regulation | Keep output voltage constant automatically when input voltage fluctuating | |
Control Function | Common DC bus | Common DC bus for several inverters, energy balanced automatically |
Torque control | Torque control without PG | |
Torque limit | “Rooter” characteristics, limit the torque automatically and prevent frequent over-current tripping during the running process | |
Wobble frequency control | Multiple triangular-wave frequency control, special for textile | |
Timing/length/counting control | Timing/length/counting control function | |
Over-voltage & over-current stall control | Limit current & voltage automatically during the running process, prevent frequent over-current & over-voltage tripping | |
Fault protection function | Up to 30 fault protections including over-current, over-voltage, under-voltage, overheating, default phase, overload, shortcut, etc., can record the detailed running status during failure & has fault automatic reset function | |
Input/output terminals | Input terminals | Programmable DI: 7 on-off inputs, 1 high-speed pulse input 2 programmable AI: AI1: 0~10V or 0/4~20mA A12: 0~10V or 0/4~20mA |
Output terminals | 1 programmable open collector output: 1 analog output (open collector output or high-speed pulse output) 2 relay output 2 analog output: 0/4~20mA or 0~10V | |
Communication terminals | Offer RS485 communication interface, support MODBUS-RTU communication protocol | |
Human machine interface | LED display | Display frequency setting, output frequency, output voltage, output current, etc. |
Multifunction key | QUICK/JOG key, can be used as multifunction key | |
Environment | Ambient temperature | -10℃~40℃, derated 4% when the temperature rise by every 1℃(40℃~50℃). |
Humidity | 90%RH or less (non-condensing) | |
Altitude | ≤1000M: output rated power, >1000M: output derated | |
Storage temperature | -20℃~60℃ | |
Storage environment | Indoor, no direct sunlight, dust, corrosive gas, flammable gas, oil mist, steam, dripping water, salt, vibration |
ME3000 products, complete models, can provide 1AC 220V / 3AC 220V ~ 660V voltage level products. The product power level covers 0.4 ~ 630kW.