HE1000 series vector high-voltage inverter is the second-generation high-voltage frequency conversion speed regulation device independently developed, designed and produced by Shenzhen MICNO Electric Co., Ltd.
The system adopts the most mainstream power unit series technology, with DSP+ARM+FPGA three-core processor as the control core, integrating the most advanced motor vector control algorithm, with high control precision, fast response, low frequency and high torque. Features.
It is very suitable for high-voltage asynchronous motor and synchronous motor energy-saving speed regulation and process improvement and has been widely used in fans, pumps, compressors, belt conveyors, hoists and other loads.
Feature 1: Three Control modes
1, High performance V/F control. (Fans, Pumps, Air compressors, etc).
2, Open loop vector control. (Belt conveyer, mill drive, fibrizer crusher, etc.)
3, Close loop vector. (Applicable to internal mixer, hoister machine, etc.)
Feature 2:Multiple types of motor drives
Support Asynchronous motors
Synchronous motors (Include PM synchronous motors)
Feature 3:Four-Quadrant Drive
Power units use IGBT for rectification, dual-energy flow, energy-saving and environmental protection.
With full rated power energy regenerative ability.
Feature 4:LVRT Low Voltage ride through
Wide voltage anti-interference capability. The system has AVR function for stable system output when the bus voltage fluctuates frequently.
No stop when instantaneous power off, during running, the system will not stop after power off in the set time. Can be set when power off 0-5s.
Feature 5:Full Brand Speed Tracking
Accurate tracking in the current rotating speed and direction of the motor without installing speed sensor
Automatic starting when power off in the set time
Feature 6:Multiple unit bypass modes
The same level bypass, when one unit is invalid, bypass it and continue to run
Neutral point drifting bypass, CPU smart calculate to ensure output stable and balance
Feature 7:Excellent Low-Frequency Control
Advanced dead area compensation technology, good low-frequency waveforms; Optimized algorithm of low-frequency oscillation suppression, no motor resonance
Feature 8:Master-slave control mode
Multi-motor drive system, realize multi-motor coordination control and obtain power balance.
Flexible grid connection, support 1 VFD drive more motors.
Optical loop connection, max support 16 motors in master-slave system.
Feature 9:Heat Dispersion Simulation
With advanced heat simulation technology, high reliable structure design for heat dispersion.
System and cabinet use unique air flue, reduce dust accumulation.
PCB/PCBA duel sides covered with conformal coatings, excellent corrosive property to raise IP level.
Item | Two quadrant | Four quadrant | |||||||||
Input | Voltage Level | AC 3PH | AC 3PH | ||||||||
3kV | 6kV | 4.16kV | 6kV | 6.6kV | 10kV | 11kV | 6kV | 10kV | |||
Input voltage | -15%~+10% | ||||||||||
Input frequency | 50/60Hz;±5% | ||||||||||
Input power factor | ≧0.97(Full load) | ||||||||||
System efficiency | ≧96%(Full load) | ||||||||||
Input current harmonic | ≦4% | ≦2% | ≦4% | ||||||||
Output | Output voltage | 0~Rated voltage | |||||||||
Output frequency | 0~120Hz(customizable) | ||||||||||
Output current harmonic | ≦4% | ≦2% | ≦4% | ||||||||
Control performance | Control mode | Vector control without PG, V/F control ,Vector control with PG | |||||||||
Speed ratio | 1:50(VF);1:100(SVC);1:200(VC) | ||||||||||
Speed control accuracy | ±1%(VF);±0.4%(SVC);±0.2%(VC) | ||||||||||
Torque response time | <200ms(SVC);<100ms(VC) | ||||||||||
Starting torque | 0.5Hz 150% rated torque (SVC); 0Hz 180% rated torque (VC) | ||||||||||
Overload protection | 120% of the rated current: 2 mins;150% of the rated current: 5 s;200% of the rated current : protect immediately | ||||||||||
ACC/DEC time | 0-3600s(customized) | ||||||||||
Feedback control method | Synchronous rectification control technology | ||||||||||
Feedback ability | 100%,The maximum feedback power of the inverter is the same as the maximum | ||||||||||
user Terminal | Digital input | 8 channels digital input(Scalable, programmable) | |||||||||
Digital output | 8 channels relay output(Scalable, programmable) | ||||||||||
Analog input | 3 channels: AI1, AI2: 0~10V/4~20mA; AI3: -10V~10V | ||||||||||
Analog output | 4 channels: AO1, AO2, AO3, AO4: 0~10V/4~20mA | ||||||||||
High speed pulse input | 1 channel: Input range 0~50kHz | ||||||||||
High speed pulse output | 1 channel: Output range 0~50kHz | ||||||||||
Protection function | System | Overcurrent, overvoltage, undervoltage, motor overload, inverter overload, input phase loss, output phase loss, Overheating, temperature controller fault, communication fault, access fault, uplink communication fault, downlink communication fault, fan overheating | |||||||||
Unit | Optical fiber uplink communication fault, optical fiber downlink communication fault, overvoltage, undervoltage, power supply overheating, input phase loss, VCE fault, bypass failure | ||||||||||
HMI | touch screen | ||||||||||
Communication method | Modbus, RS485 interface, Optional: Profibus-DP, Ethernet | ||||||||||
Installation method | Cabinet mounting | ||||||||||
Protection degree | IP30 | ||||||||||
Noise degree | ≤75dB | ||||||||||
Feed in and out method | Bottom in and out; other methods are optional | ||||||||||
Control power supply | AC 380V±10% | ||||||||||
MTBF | 50000h | ||||||||||
Temperature of running environment | -5℃~+40℃, derate 1.5% for every additional 1℃ if the temperature is above 40 ℃ and the maximum temperature is 50℃; run without load if the temperature reaches 60℃ | ||||||||||
Humidity | 5%~95%(non-condensing) | ||||||||||
Altitude | Below 1000m; derate 1% for every additional 100m if the sea level is above 1000m | ||||||||||
Storage | Keep away from dust, direct sunlight, flammable or corrosive gas, oil, steam or vibration | ||||||||||
Vibration | Below 0.59g |
6KV | Model | Capacity(KVA) | 10KV | Model | Capacity(KVA) |
HE1000-0220-0027-06 | 275 | HE1000-0220-0017-10 | 275 | ||
HE1000-0250-0030-06 | 315 | HE1000-0250-0019-10 | 315 | ||
HE1000-0280-0033-06 | 350 | HE1000-0280-0021-10 | 350 | ||
HE1000-0315-0037-06 | 400 | HE1000-0315-0024-10 | 400 | ||
HE1000-0355-0042-06 | 450 | HE1000-0355-0027-10 | 450 | ||
HE1000-0400-0048-06 | 500 | HE1000-0400-0030-10 | 500 | ||
HE1000-0450-0054-06 | 560 | HE1000-0450-0033-10 | 560 | ||
HE1000-0500-0060-06 | 630 | HE1000-0500-0037-10 | 630 | ||
HE1000-0560-0067-06 | 700 | HE1000-0560-0041-10 | 700 | ||
HE1000-0630-0075-06 | 800 | HE1000-0630-0046-10 | 800 | ||
HE1000-0710-0084-06 | 900 | HE1000-0710-0051-10 | 900 | ||
HE1000-0800-0095-06 | 1000 | HE1000-0800-0057-10 | 1000 | ||
HE1000-0900-0106-06 | 1100 | HE1000-0900-0064-10 | 1100 | ||
HE1000-1000-0118-06 | 1250 | HE1000-1000-0071-10 | 1250 | ||
HE1000-1120-0132-06 | 1400 | HE1000-1120-0079-10 | 1400 | ||
HE1000-1250-0146-06 | 1600 | HE1000-1250-0088-10 | 1600 | ||
HE1000-1400-0164-06 | 1750 | HE1000-1400-0098-10 | 1750 | ||
HE1000-1600-0185-06 | 2000 | HE1000-1600-0112-10 | 2000 | ||
HE1000-1800-0220-06 | 2250 | HE1000-1800-0127-10 | 2250 | ||
HE1000-2000-0229-06 | 2500 | HE1000-2000-0141-10 | 2500 | ||
HE1000-2240-0261-06 | 2800 | HE1000-2240-0157-10 | 2800 | ||
HE1000-2300-0261-06 | 2800 | HE1000-2300-0158-10 | 2800 | ||
HE1000-2500-0281-06 | 3150 | HE1000-2500-0175-10 | 3150 | ||
HE1000-2800-0324-06 | 3500 | HE1000-2800-0205-10 | 3500 | ||
HE1000-3150-0363-06 | 4000 | HE1000-3150-0230-10 | 4000 | ||
HE1000-3550-0428-06 | 4500 | HE1000-3550-0260-10 | 4500 | ||
HE1000-4000-0482-06 | 5000 | HE1000-4000-0290-10 | 5000 | ||
HE1000-4500-0542-06 | 5600 | HE1000-4500-0326-10 | 5600 | ||
HE1000-5000-0595-06 | 6300 | HE1000-5000-0362-10 | 6300 | ||
HE1000-5600-0405-10 | 7000 | ||||
HE1000-6300-0456-10 | 8000 | ||||
HE1000-7100-0512-10 | 9000 |
Leave us Message