• KE300A-05 Series Washing Machine Special Inverter

KE300A-05 Series Washing Machine Special Inverter

KE300A-05 series "industrial washing machine" special inverter

It is a dedicated CNC automatic industrial washing machine. Compared with the traditional industrial washing machine drive control system, the program part has made advanced current limiting technology and hardware for the application characteristics of the three washing programs of industrial washing machine: uniform, medium and high washing Optimize the design and add a wide range of high-speed output mode for industrial washing machines to achieve the most ideal washing effect and significantly reduce the mechanical impact, so that the washing machine always works in an optimal state. Industrial washing machines are widely used in hotels, hotels, hospitals, schools, garment factories, washing plants, industrial and mining enterprises and other occasions.

  • Features
  • Specifications
  • Selection table
  • Classic Case
  • Download

Features of KE300A-05 Series Washing Machine Special Inverter

(1) Easy to install and debug

(2) Robust EMC design

(3) Modular design with very flexible configuration

(4) The main control system uses 32-bit high-speed DSP, integrated PG-free vector control, V / f control, and torque control.

(5) The optimized motor parameter identification model can effectively reduce the sensitivity to motor parameters and make self-learning more accurate. Support static self-learning.

(6) High starting torque: In the vector control mode without PG, at 0.5 Hz, it can provide 150% of the starting torque;

(7) Excellent robust performance can ensure that the load can start and stop quickly;

(8) Fast dynamic response: Under the vector control mode without PG, the dynamic response time is less than 20ms;

(9) Fast current limiting function: it can quickly limit the current within the protection point, reducing the probability of frequent overcurrent alarm failure.

(10) High power factor output, reduced reactive power loss, and no large current impact during soft start.

(11) Built-in PID regulator can easily form a closed-loop control system for process quantities such as temperature, pressure and flow.

(12) It has automatic fault reset and power-off reset functions to ensure continuous production and production efficiency.

(13) Adopting advanced power module driving mode, high power factor, can effectively suppress harmonics, and eliminate interference to peripheral control loops and sensors during inverter operation.

(14) Perfect protection functions: overvoltage / under-voltage protection, inverter overheat protection, ground fault protection, short circuit protection, overcurrent protection, overload protection, etc.


Specifications of KE300A-05 Series Washing Machine Special Inverter

Item

Technical Index

Specification

Input

Input voltage

1AC 220V±15%, 3AC 380V±15%

Input frequency

47~63Hz

Output

Output voltage

0~rated input voltage

Output frequency

V/f control: 0~3000Hz Sensorless vector control: 0~300Hz

Operation command mode

Keypad control Terminal control Serial communication control

Frequency setting mode

Digital setting, analog setting, pulse frequency setting, serial communication setting, multi-step speed setting & simple PLC, PID setting, etc. These frequency settings can be combined & switched in various modes.

Overload capacity

G model: 150% 60s, 180% 10s, 200% 3s P model: 120% 60s, 150% 10s, 180% 3s

Starting torque

0.5Hz/150% (SVC); 1Hz/150% (V/f)

Speed adjustment range

1:100 (SVC), 1:50 (V/f)

Carrier frequency

1.0-16.0kHz,automatically adjusted according to temperature and load characteristics

Frequency accuracy

Digital setting: 0.01Hz Analog setting: maximum frequency * 0.05%

Torque boost

Automatically torque boost; manually torque boost: 0.1%~30.0%

V/f curve

Three types: linear, multiple point and square type (1.2 power, 1.4 power, 1.6 power, 1.8 power, square)

Acceleration/decele ration mode

Straight line/S curve; four kinds of acceleration/deceleration time, range: 0.1s~3600.0s

DC braking

DC braking when starting and stopping DC braking frequency: 0.0Hz~maximum frequency, braking time: 0.0s~100.0s

Jog operation

Jog operation frequency: 0.0Hz~maximum frequency Jog acceleration/deceleration time: 0.1s~3600.0s

Simple PLC & multi-step speed operation

It can realize a maximum of 16 segments speed running via the built-in PLC or control terminal.

Built-in PID

Built-in PID control to easily realize the close loop control of the process parameters (such as pressure, temperature, flow, etc.)

Automatic voltage regulation

Keep output voltage constant automatically when input voltage fluctuating

Control Function

Common DC bus

Common DC bus for several inverters, energy balanced automatically

Torque control

Torque control without PG

Torque limit

“Rooter” characteristics, limit the torque automatically and prevent frequent over-current tripping during the running process

Wobble frequency control

Multiple triangular-wave frequency control, special for textile

Timing/length/counting control

Timing/length/counting control function

Over-voltage & over-current stall control

Limit current & voltage automatically during the running process, prevent frequent over-current & over-voltage tripping

Fault protection function

Up to 30 fault protections including over-current, over-voltage, under-voltage, overheating, default phase, overload, shortcut, etc., can record the detailed running status during failure & has fault automatic reset function

Input/output terminals

Input terminals

Programmable DI: 7 on-off inputs, 1 high-speed pulse input 2 programmable AI: AI1: 0~10V or 0/4~20mA                                A12: 0~10V or 0/4~20mA

Output terminals

1 programmable open collector output: 1 analog output (open collector output or high-speed pulse output) 2 relay output 2 analog output: 0/4~20mA or 0~10V

Communication terminals

Offer RS485 communication interface, support MODBUS-RTU communication protocol

Human machine interface

LED display

Display frequency setting, output frequency, output voltage, output current, etc.

Multifunction key

QUICK/JOG key, can be used as multifunction key

Environment

Ambient temperature

-10℃~40℃, derated 4% when the temperature rise by every 1℃(40℃~50℃).

Humidity

90%RH or less (non-condensing)

Altitude

≤1000M: output rated power, >1000M: output  derated

Storage temperature

-20℃~60℃

Storage environment

Indoor, no direct sunlight, dust, corrosive gas, flammable gas, oil mist, steam, dripping water, salt, vibration


Inverter Model

Motor

Rated Input

Current (A)

Rated Output

Current (A)


KW

HP

1AC 220V/230V/240V -15%~15%


KE300A-05-0R4G-S2

0.4

0.5

5.4

2.3

KE300A-05-0R7G-S2

0.75

1.0

8.2

4.0

KE300A-05-1R5G-S2

1.5

2.0

14.0

7.0

KE300A-05-2R2G-S2

2.2

3.0

23.0

9.6

KE300A-05-004G-S2

4.0

5.2

25.0

15.0

KE300A-05-5R5G-S2

5.5

7.2

38.0

23.0

KE300A-05-7R5G-S2

7.5

10.0

50.0

32.0

3AC 380V/400V/415V -15%~15%

KE300A-05-0R7G/1R5P-T4

0.75/1.5

1/2

3.4/5.0

2.1/3.8

KE300A-05-1R5G/2R2P-T4

1.5/2.2

2/3

5.0/6.8

3.8/6

KE300A-05-2R2G/004P-T4

2.2/4.0

3/5

6.8/10

6/9

KE300A-05-004G/5R5P-T4

4.0/5.5

5/7.5

10/15

9/13

KE300A-05-5R5G/7R5P-T4

5.5/7.5

7.5/10

15/20

13/17

KE300A-05-7R5G/011P-T4

7.5/11

10/15

20/26

17/25

KE300A-05-011G/015P-T4

11/15

15/20

26/35

25/32

KE300A-05-015G/018P-T4

15/18.5

20/25

35/38

32/37

KE300A-05-018G/022P-T4

18.5/22

25/30

38/46

37/45

KE300A-05-022G/030P-T4

22/30

30/40

46/62

45/60

KE300A-05-030G/037P-T4

30/37

40/50

62/76

60/75

KE300A-05-037G/045P-T4

37/45

50/60

76/90

75/90

KE300A-05-045G/055P-T4

45/55

60/75

92/113

90/110

KE300A-05-055G/075P-T4

55/75

75/100

112/157

110/150

KE300A-05-075G/090P-T4

75/90

100/125

157/180

150/176

KE300A-05-090G/110P-T4

90/110

125/150

180/214

176/210