• output ac reactor1
  • output ac reactor
  • output ac reactor1
  • output ac reactor

Output AC Reactor

Smoothing circuit, efficient from IGBT motor drives, so as to extending service life of electric motors, reduce motor noise and eddy loss, reduce the leakage current resulted from the output of high harmonic. Protect the electronic power switch within the inverters with output reactors.


Reactor AC for inverter is installed next to the inverter between the inverter and water pump. The drive output reactors can smooth filter, reduce motor noise and help prolong the life of the water pump; reduce the leakage current caused by the output higher harmonic, and protect the power switch devices in the inverter. A VFD reactor can also ensure the steadier operation and higher efficiency of the water pump.

  • Features
  • Specifications
  • Selection table
  • Classic Case
  • Download

Features of AC Reactor for Inverter


  • Selection of silicon steel, ferrite magnetic material of amorphous core according to the frequency of application.

  • Excellent property due to foil winding structure, small DC resistance, strong resistance to the electromagnetic force, good overload ability in a short time.

  • F class insulation materials are used, which ensure drive reactors maintain reliable performance in harsh working conditions.

  • Designed with low magnetic flux density, the drive reactor is of high linearity, powerful overload capacity. Moreover, combined with VPI process, the noise is low.


Output AC Reactor


Application of Inverter Reactor

An output reactor for VFD is used to protect the motor if the wiring distance between the VFD and motor is very long. The drive generates a high-frequency PWM three-phase output and noise spikes are generated on the leading edge of these signals. So we suggest:

If the distance between the inverter and water pump exceeds 50 meters, a VFD Reactor is suggested. 

If the distance exceeds 100 meters, you must add the VFD Reactor and enlarge the inverter model.

Technical Specifications of AC Inverter Reactor


  • Rated Operating Voltage: 380V690V1140V 50Hz/60Hz

  • Operating Frequency: 0~120Hz(Higher than 120Hz need customization)

  • Current Range: 5A~1600A

  • Operation Ambient Temperature:-25℃~50℃

  • Dielectric Strength: Core-winging, AC 3000V/50Hz/5mA in 60s free of damage(test in a factory)

  • Insulation Resistance: Core-winging, DC 1000V, resistance≥100M ohm

  • Inverter reactor's noise: <80dB(to be measured at the point 1 meter away from the reactor horizontally)

  • Protection class: IP00

  • Insulation class: F

  • Standard: GB 19212.1-2008 GB/T1094.6-2011


Model Description of AC Reactor for Inverter

Model Description


380V AC Output Reactor(1% impendence) Selection Guide


380V-AC-Output-Reactor-Selection-Guide.jpg

Leave us Message